PRODUCTS

PRODUCTS

GE Veridri
Brand:New arrow electron

Veridri humidity analyzer provides more simple, accurate and reliable gas humidity analysis and measurement solutions for dry gas manufacturers and other OEM manufacturers at very competitive prices. Veridri two-wire loop power supply, 4 to 20 mA output, and the measurement range covers all temperature ranges with dew point from - 110 ° C to 40 ° C. When the pressure is constant, the ppmv value can also be output, ranging from 0 to 10000 ppmv. When the required output is ppmv, the on-site pressure parameters must be provided to the manufacturer when ordering.

Excellent humidity sensing technology

Veridri uses alumina moisture probe technology. Ge sensor and measurement probes have fast response and excellent stability. The strict calibration standard traceable to NIST, ultra-high sensitivity, extraordinary calibration stability, ultra-wide measurement range and fast response make GE alumina moisture probe establish the performance and measurement value standard of industrial moisture measurement. It is applicable to the measurement of moisture from trace to constant in laboratory and industrial process gases and non-aqueous liquids. The test environment used by each probe in the calibration process is accurately generated by the flow, temperature and pressure measurement equipment traceable to the National Institute of technical calibration (NIST).

Easy installation

Veridri is a small transmitter specially designed for small space in OEM applications. It can be installed directly on the detection point or in the sampling system as needed. If required, Ge sensing and measurement can design and manufacture the system separately according to the user's special application. More mts5 online dew point for you to choose

technical parameter

Measuring range: - 110 ~ 20 ℃

Operating temperature: - 40 ℃ ~ 60 ℃

Storage temperature: ≤ 70 ℃

Accuracy: ± 2 ℃ (range from - 65 ℃ ~ 40 ℃)

± 3 ℃ (range - 80 ℃ ~ - 66 ℃)

Repeatability: ± 0.5 ℃ (range - 65 ℃ ~ 40 ℃)

± 1.0 ℃ (range - 80 ℃ ~ - 66 ℃)

Response time: 5 seconds (63% change)

Power supply: 7 ~ 28 VDC (loop power supply, power supply provided by the customer)

Output: 4 ~ 20 mA

Output resolution: 0.01 Ma

Cable: standard 2 m

Process connection: 3 / 4unf-16

Operating pressure: 345 bar

Protection grade: type 4x, IP67

Weight: 140g

Moisture probe: alumina moisture probe

Calibration: each probe is calibrated separately by computer. Compared with the known water content, the calibration can be traced to the National Bureau of technical standards (NIST).

Calibration cycle: Ge recommends recalibrating the probe every 6 to 12 months (according to the actual use).

Comply with European standards, EMC 89 / 336 / EEC and ped for DN < 25

97/23/EC


Return